{"en":"SPH Series Cross Flow Film Fill","es":"","ru":"","zh-cn":"SPH横流填料"}

SPH Series Cross Flow Film Fill

SPH Series Cross Flow Film Fill

SPH series cross flow film fill is using PVC/PP sheet material, with the advanced technical, long lifetime, low resistance, light weight. Fully solve gas-liquid exchange, reasonable design, not easy to hide dirt, easy to install. Fill width is in 850mm and 1000mm.


Newin SPH series fill is used for cross flow cooling tower, cooling tower PVC sheet filler with the advanced technical, long lifetime, low resistance, light weight. During the service, the fill can increase the water flow process. Fully solve gas-liquid exchange, reasonable design, not easy to hide dirt, easy to install.It is widely used in Square cooling tower.
 

Features

Applicable for cross flow square type cooling towers.
■ Using modified PVC sheet, unique modified formula makes the infill strong resistance and high durability.
■ Vac form special processing, the inner side (fan side) edge with integrated liquid baffle plate, and controls the drift loss of water in minimum value. and maximize the heat exchange performance of the water and air.
■ Standard heat temperature of 50 ° C, heatproof specification (optional) can use up to 80 ° C.
 

Properties 

With different request in SPH film fill, like length and width, materials or thickness, etc, please inform us your detailed request to get correct solution and offer. Newin could cover all customer requirements. Fill media in flame retardant or anti-bacterial execution are also available on request.
Module Length (Max)  mm 1000
Module Width   mm 850/1000
Module Depth   mm
Flute Height  mm 16
Flute Corrugation Angle  degrees
Surface Area  m2/m3 176
Sheet Thickness - Before Forming  mm 0.32
Sheet Thickness - After  Forming  mm 0.28
Max. application temp. (short time) - PVC  °C 60
Max.operating temp. (short time) - High temp.  °C 80
Customized size and thickness available for special request. Contact Newin for details.
 

Structure & Installation Drawing

Newin supply structure & installtion drawing advice with jobsite storage advice and quality control report along with shipment to make attention to customers when they receive the materals. OEM or special mold design also available on request.


Application & Usage

Newin SPH Film Fill is applicable for other brands crossflow cooling tower series of KGKX Series Field Erected, with SGS test in ASTM Standards to keep high quality infill to get the high efficiency of the cooling tower. Inform us the tower model or size, we will estimate the Nos of sheets needed for your cooling tower replacing.


Applicable Commercial Standards

Sheets material is strictly followed below SGS test with ASTM standards. Each property or all properties as below tested by your products are also vailable on request.
Property Test Method Values
Specific Gravity ASTM D792-13
Method B
1.426g/cm3
Oxygen Index ASTM D2863-13 34.50%
Tear Strength ASTM D1004-13 X direction 111 N
Y direction 121 N
Tensible Test ASTM D 882-12 Tensile Strength X direction 51.1 MPa
Y direction 45.3 Mpa
Elongation at
Break
X direction 87%
Y direction 56%
Values shown above based on SGS Test No.: GZIN1708039662PS by Newin
Statements and methods presented are based upon the best available information and practices 
known to Newin. Conditions of use may vary and are beyond control, the user should undertake 
sufficient tests to determine the suitability for any intended use of the material.
 

Filed Data for Cross Flow Film Fill Replacement

Fill in below measurements data for your maintenance cooling tower or reparing projects demand quality and reliability, count on Newin, site visit or maintenance service, engineered to fit the cooling tower fills or components. 

Please make sure your contact information is correct. Your message will be sent directly to the recipient(s) and will not be publicly displayed. We will never distribute or sell your personal information to third parties without your express permission.