{"en":"HOH Series Cross Flow Film Fill","es":"","ru":"","zh-cn":"HOH系列薄膜式填料"}

HOH Series Cross Flow Film Fill

HOH Series Cross Flow Film Fill

HOH series is a hanging film type cooling tower fill which spreads the water into a thin film, flowing over large vertical surfaces, promoting maximum exposure to air flow. Width is available from 810mm to 1010mm to satisfy different cooling towers request.


Newin HOH Cross Flow Film Fill is a hanging film type cooling tower fill which incorporates highly efficient cellular drift eliminator and molded with the air inlet louver, spreads the water through the thin film, flowing over large vertical surfaces, promoting maximum exposure to air flow to get higher cooling efficiency. This type of fill provides much more water surface exposure per cubic foot than splash type fill.
 

Features

Applicable for cross flow type cooling towers.
■ Hanging or glue is available.
■ Incorporates highly efficient cellular drift eliminators, intergrally molded within the fill sheet.

■ Louvers are also integrally molded within the fill sheets preventing water from escaping and assuring precise air distribution throughout wide variations in airflow.
■ Thermoformed from PVC with a flame spread rating and considered self extinguishing.

Properties 
With different request in HOH film fill, like length and width, materials or thickness, etc, please inform us your detailed request to get correct solution and offer. Newin could cover all customer requirements. Fill media in flame retardant or anti-bacterial execution are also available on request.
Module Length (Max)  mm 3500
Module Width   mm 810 / 910 / 1010
Module Depth   mm
Flute Height  mm 19
Flute Corrugation Angle  degrees
Surface Area  m2/m3 150
Sheet Thickness - Before Forming  mm 0.32
Sheet Thickness - After  Forming  mm 0.28
Max. application temp. (short time) - PVC  °C 60
Max.operating temp. (short time) - High temp.  °C 80
Customized size and thickness available for special request. Contact Newin for details.
 

Structure & Installation Drawing

Newin supply structure & installtion drawing advice with jobsite storage advice and quality control report along with shipment to make attention to customers when they receive the materals. OEM or special mold design also available on request.


Application & Usage

Newin HOH Film Fill is also applicable for cross flow cooling tower series of MK field erected, with SGS test in ASTM Standards to keep high quality infill to get the high efficienty of the cooling tower. Inform us the tower model or size, we will estimate the Nos of sheets needed for your cooling tower replacing.


Applicable Commercial Standards

Sheets material is strictly followed below SGS test with ASTM standards. Each property or all properties as below tested by your products are also vailable on request.
Property Test Method Values
Specific Gravity ASTM D792-13
Method B
1.426g/cm3
Oxygen Index ASTM D2863-13 34.50%
Tear Strength ASTM D1004-13 X direction 111 N
Y direction 121 N
Tensible Test ASTM D 882-12 Tensile Strength X direction 51.1 MPa
Y direction 45.3 Mpa
Elongation at
Break
X direction 87%
Y direction 56%
Values shown above based on SGS Test No.: GZIN1708039662PS by Newin
Statements and methods presented are based upon the best available information and practices 
known to Newin. Conditions of use may vary and are beyond control, the user should undertake 
sufficient tests to determine the suitability for any intended use of the material.
 

Filed Data for Cross Flow Film Fill Replacement

Fill in below measurements data for your maintenance cooling tower or reparing projects demand quality and reliability, count on Newin, site visit or maintenance service, engineered to fit the cooling tower fills or components. 

Please make sure your contact information is correct. Your message will be sent directly to the recipient(s) and will not be publicly displayed. We will never distribute or sell your personal information to third parties without your express permission.

Related Parts