Newin SHH series cross flow film fill is used for square cooling tower, with the advanced technical, long lifetime, low resistance, light weight. The surface is smooth and bright, pressure strength is strong, it will not break when touched, non-toxic and non-irritating, more safer.High quality new PVC raw material, guaranteed quality, durability, through the test and production operation show that the cooling effect is good.
Features
■ Using modified PVC sheet, unique modified formula makes the infill strong resistance and high durability.
■ Vac form special processing, the inner side (fan side) edge with integrated liquid baffle plate, and controls the drift loss of water in minimum value, and maximize the heat exchange performance of the water and air.
■ Standard heat temperature of 50 ° C, heatproof specification (optional) can use up to 80 ° C.
Properties
With different request in SHH film fill, like length and width, materials or thickness, etc, please inform us your detailed request to get correct solution and offer. Newin could cover all customer requirements. Fill media in flame retardant or anti-bacterial execution are also available on request.
Module Width |
mm |
950/1270 |
Module Height |
mm |
950 |
Module Depth |
mm |
— |
Flute Height |
mm |
20 |
Flute Corrugation Angle |
degrees |
- |
Surface Area |
m2/m3 |
147 |
Sheet Thickness - Before Forming |
mm |
0.32 |
Sheet Thickness - After Forming |
mm |
0.28 |
Max. application temp. (short time) - PVC |
°C |
60 |
Max.operating temp. (short time) - High temp. |
°C |
80 |
Customized size and thickness available for special request. Contact Newin for details. |
Structure & Installation Drawing
Newin supply structure & installtion drawing advice with jobsite storage advice and quality control report along with shipment to make attention to customers when they receive the materals. OEM or special mold design also available on request.
Application & Usage
Newin SHH Film Fill is applicable for other brands crossflow cooling tower series of SNC-U, SDC-U Field Erected, with SGS test in ASTM Standards to keep high quality infill to get the high efficiency of the cooling tower. Inform us the tower model or size, we will estimate the Nos of sheets needed for your cooling tower replacing.
Applicable Commercial Standards
Sheets material is strictly followed below SGS test with ASTM standards. Each property or all properties as below tested by your products are also vailable on request.
Property |
Test Method |
Values |
Specific Gravity |
ASTM D792-13
Method B |
1.426g/cm3 |
Oxygen Index |
ASTM D2863-13 |
34.50% |
Tear Strength |
ASTM D1004-13 |
X direction |
111 N |
Y direction |
121 N |
Tensible Test |
ASTM D 882-12 |
Tensile Strength |
X direction |
51.1 MPa |
Y direction |
45.3 Mpa |
Elongation at
Break |
X direction |
87% |
Y direction |
56% |
Values shown above based on SGS Test No.: GZIN1708039662PS by Newin |
Statements and methods presented are based upon the best available information and practices
known to Newin. Conditions of use may vary and are beyond control, the user should undertake
sufficient tests to determine the suitability for any intended use of the material. |
Filed Data for Cross Flow Film Fill Replacement
Fill in below measurements data for your maintenance cooling tower or reparing projects demand quality and reliability, count on Newin, site visit or maintenance service, engineered to fit the cooling tower fills or components.