Newin MBH Film Fill is a hanging film type cooling tower fill which incorporates highly efficient cellular drift eliminator and molded with the air inlet louver, spreads the water through the thin film, flowing over large vertical surfaces, promoting maximum exposure to air flow to get higher cooling efficiency. This type of fill provides much more water surface exposure per cubic foot than splash type fill.
Features
■ Applicable for cross flow type cooling towers.
■ Hanging or glue is available.
■ Incorporates highly efficient cellular drift eliminators, intergrally molded within the fill sheet.
■ Louvers are also integrally molded within the fill sheets preventing water from escaping and assuring precise air distribution throughout wide variations in airflow.
■ Thermoformed from PVC with a flame spread rating and considered self extinguishing.
Properties
With different request in MBH film fill, like length and width, materials or thickness, etc, please inform us your detailed request to get correct solution and offer. Newin could cover all customer requirements. Fill media in flame retardant or anti-bacterial execution are also available on request.
Module Length (Max) |
mm |
4000 |
Module Width |
mm |
800/900/1000/1100/1200 |
Module Depth |
mm |
— |
Flute Height |
mm |
19 |
Flute Corrugation Angle |
degrees |
- |
Surface Area |
m2/m3 |
150 |
Sheet Thickness - Before Forming |
mm |
0.32 |
Sheet Thickness - After Forming |
mm |
0.28 |
Max. application temp. (short time) - PVC |
°C |
60 |
Max.operating temp. (short time) - High temp. |
°C |
80 |
Customized size and thickness available for special request. Contact Newin for details. |
Structure & Installation Drawing
Newin supply structure & installtion drawing advice with jobsite storage advice and quality control report along with shipment to make attention to customers when they receive the materals. OEM or special mold design also available on request.
Application & Usage
Newin MBH Film Fill is applicable for cross flow cooling towers, with SGS test in ASTM Standards to keep high quality infill to get the high efficienty of the cooling tower. Inform us the tower model or size, we will estimate the Nos of sheets needed for your cooling tower replacing.
Applicable Commercial Standards
Sheets material is strictly followed below SGS test with ASTM standards. Each property or all properties as below tested by your products are also vailable on request.
Property |
Test Method |
Values |
Specific Gravity |
ASTM D792-13
Method B |
1.426g/cm3 |
Oxygen Index |
ASTM D2863-13 |
34.50% |
Tear Strength |
ASTM D1004-13 |
X direction |
111 N |
Y direction |
121 N |
Tensible Test |
ASTM D 882-12 |
Tensile Strength |
X direction |
51.1 MPa |
Y direction |
45.3 Mpa |
Elongation at
Break |
X direction |
87% |
Y direction |
56% |
Values shown above based on SGS Test No.: GZIN1708039662PS by Newin |
Statements and methods presented are based upon the best available information and practices
known to Newin. Conditions of use may vary and are beyond control, the user should undertake
sufficient tests to determine the suitability for any intended use of the material. |
Filed Data for Cross Flow Film Fill Replacement
Fill in below measurements data for your maintenance cooling tower or reparing projects demand quality and reliability, count on Newin, site visit or maintenance service, engineered to fit the cooling tower fills or components.