Newin HAN series counter flow film fill applicable for counter flow cooling tower, reasonable design, durability, good cooling effect, small ventilation resistance, strong hydrophilic ability and large contact area.It has a wide range of application, good laminar flow state, and the particle settlement is not disturbed by turbulence, excellent fire resistant qualities.100% new material to make the great quality of infill.
Features
■ Applicable for counter flow type cooling towers, specially designed to induce highly turbulent mixing of the air and water for superior heat transfer.
■ The fill is constructed of PVC, which the cross-fluted sheets are bonded together, the structural integrity of the fills is greatly enhanced, has excellent fire resistant qualities.
■ Well Long service life with minimal maintenance.
■ 100% new material to make the great quality of infill.
Properties
With different request in HAN film fill, like length and width, materials or thickness, etc, please inform us your detailed request to get correct solution and offer. Newin could cover all customer requirements. Fill media in flame retardant or anti-bacterial execution are also available on request.
Module Length (Max) |
mm |
2000 |
Module Width |
mm |
500/610 |
Module Depth |
mm |
— |
Flute Height |
mm |
22/20 |
Flute Corrugation Angle |
degrees |
- |
Surface Area |
m2/m3 |
125 / 142 |
Sheet Thickness - Before Forming |
mm |
0.35 |
Sheet Thickness - After Forming |
mm |
0.3 |
Max. application temp. (short time) - PVC |
°C |
60 |
Max.operating temp. (short time) - High temp. |
°C |
80 |
Customized size and thickness available for special request. Contact Newin for details. |
Structure & Installation Drawing
Newin supply structure & installtion drawing advice with jobsite storage advice and quality control report along with shipment to make attention to customers when they receive the materals. OEM or special mold design also available on request.
Application & Usage
Newin HAN Film Fill is applicable for counter flow cooling towers, any induced draft or natural draft cooling tower, with SGS test to keep high quality infill to get the high efficiency of the cooling tower. Inform us the tower model or size, we will estimate the Nos of sheets needed for your cooling tower replacing.
Applicable Commercial Standards
Sheets material is strictly followed below SGS test with ASTM standards. Each property or all properties as below tested by your products are also vailable on request.
Property |
Test Method |
Values |
Specific Gravity |
ASTM D792-13
Method B |
1.426g/cm3 |
Oxygen Index |
ASTM D2863-13 |
34.50% |
Tear Strength |
ASTM D1004-13 |
X direction |
111 N |
Y direction |
121 N |
Tensible Test |
ASTM D 882-12 |
Tensile Strength |
X direction |
51.1 MPa |
Y direction |
45.3 Mpa |
Elongation at
Break |
X direction |
87% |
Y direction |
56% |
Values shown above based on SGS Test No.: GZIN1708039662PS by Newin |
Statements and methods presented are based upon the best available information and practices
known to Newin. Conditions of use may vary and are beyond control, the user should undertake
sufficient tests to determine the suitability for any intended use of the material. |
Filed Data for Counter Flow Film Fill Replacement
Fill in below measurements data for your maintenance cooling tower or reparing projects demand quality and reliability, count on Newin, site visit or maintenance service, engineered to fit the cooling tower fills or components.